Natalya Kramarova

and 7 more

In this study, we present evaluation of version 3 ozone products derived from the DSCOVR EPIC instrument. EPIC’s total and tropospheric ozone columns have been compared with correlative satellite and ground-based measurements at time scales from daily averages to monthly means. We found that the agreement improves if we only accept retrievals derived from the EPIC 317 nm triplet and limit solar zenith and satellite looking angles to 70°. With such filtering in place, the comparisons of EPIC total columns with correlative satellite and ground-based data show mean differences within ±5-7 DU (or 1.5-2.5%). The biases with OMI and OMPS NM tend to be mostly negative in the Southern Hemisphere (SH), while there are no clear latitudinal patterns in ground-based comparisons. Evaluation of the EPIC ozone time series at different ground-based stations with the correlative ground-based Brewer and Pandora instruments and ozonesondes demonstrated good consistency in capturing ozone variations at daily, weekly and monthly scales with a persistently high correlation (r2>0.9) for total and tropospheric columns. We examined the quality of EPIC tropospheric ozone columns by comparing with ozonesondes at 12 stations and found that differences in tropospheric column ozone are within ±2.5 DU (or ~±10%) after removing a constant 3 DU offset at all stations between EPIC and sondes. The analysis of the time series of zonally averaged EPIC tropospheric ozone revealed a statistically significant drop of ~2-4 DU (~5-10%) over the entire NH in spring and summer of 2020, which is partially related to the unprecedented Arctic stratospheric ozone losses in winter-spring 2019/2020 and reductions in ozone precursor pollutants due to the COVID-19 pandemic.

Caroline R. Nowlan

and 14 more

We describe new publicly-available, multi-year formaldehyde (HCHO) data records from the Ozone Mapping and Profiler Suite (OMPS) nadir mapper (NM) instruments on the Suomi NPP and NOAA-20 satellites. The OMPS-NM instruments measure backscattered UV light over the globe once per day, with spatial resolutions close to nadir of 50 × 50 km² (OMPS/Suomi-NPP) and 17 × 17 km² or 12 × 17 km² (OMPS/NOAA-20). After a preliminary instrument line shape and wavelength calibration using on-orbit observations, we use the backscatter measurements in a direct spectral fit of radiances, in combination with a nadir reference spectrum collected over a clean area, to determine slant columns of HCHO. The slant columns are converted to vertical columns using air mass factors derived through scene-by-scene radiative transfer calculations. Finally, a correction is applied to account for background HCHO in the reference spectrum, as well as any remaining high-latitude biases. We investigate the consistency of the OMPS products from Suomi NPP and NOAA-20 using long-term monthly means over 12 geographic regions, and also compare the products with publicly-available TROPOMI HCHO observations. OMPS/Suomi-NPP and OMPS/NOAA-20 monthly mean HCHO vertical columns are highly consistent (r = 0.98), with low proportional (2 %) and offset (2×10¹⁴ molecules cm⁻²) biases. OMPS HCHO monthly means are also well-correlated with those from TROPOMI (r = 0.92), although they are consistently 10±16 % larger in polluted regions (columns >8×10¹⁵ molecules cm⁻²). These differences result primarily from differences in air mass factors.